6. Camera calibration

Bakelite plate
(120x100x2t)
  1. Camera can be calibrated in the MagicEngrave program.

e7main39.png

  1. Use the e7main5.pnge7main6.png button to adjust the red line (that appears on the screen) to center of the clamp. Once the red line is adjusted to the center, click Next.

e7main40.png

  1. Place and secure the bakelite to the clamp. Set the calibration area to 90 x 70mm then click Create Line. Check the calibration results then click OK.

e7main41.png

  1. Press and hold the e7main4.png button (for more than 3 seconds) until it beeps to start engraving. A rectangle will be engraved for calibration.

  1. Align the red corner marks to the calibration line corners with the mouse or keyboard.

e7main42.png

  1. Check the calibration results on the program. Be sure that the red lines are marked over the calibration lines. Click OK to complete the calibration.

e7main43.png



Go to the E4 Clibration➜