2. Probe Calibration

  1. Secure a flat material to the clamp.

  1. Press the e7main2.png button to enter menu mode.

  1. Use e7main3.pnge7main4.pnge7main5.pnge7main6.png buttons. When 3.Calibration menu appears on the LCD window, press and hold e7main7.png button to run the menu.

  1. Select the “2.Probe” then press and hold e7main7.png button to run the menu.

  1. When “Probe” appears on the LCD window (as shown below), press Start button on the LCD window, then press e7main5.pnge7main6.png button to lower the tool until it comes in contact to the material. Loosen the tool fixing bolt with a wrench to lower the tool or lift the material with your hand to make the tool and material come in contact.

e7main8.png

  1. Long-press and hold e7main7.png button (for more than 2 seconds) until it beeps to confirm that the setting is saved. The probe will then measure the material then the machine will measure the tool.

  1. Press Check button to start a test run. Check whether the tool draws four lines on the materials or not. If two lines out of four lines are shown on the material, then it is correct. If three lines are shown, press e7main9.png button to raise it by 0.05mm, and if one line is shown, press Z axis e7main10.png button to lower it by 0.05mm (※0.05mm per line.)

e7main11.png

  1. Long-press and hold e7main7.png button (for more than 3 seconds) until it beeps to confirm that the setting is saved.


Go to the E4 Clibration➜