Redt Help Center

Ring Scan

What is the Ring Scan Feature?

The Ring Scan feature uses the built-in camera to scan the position and shape of a ring.
Based on the scanned data, the software automatically calculates and corrects the laser marking position.
With conventional rotary marking, the user must manually align the ring before engraving.
Using the Ring Scan function, however, the software determines the marking position from the scanned data, improving both positioning accuracy and repeatability for ring engraving operations.


Supported Versions for Ring Scan

  1. Firmware v3.2 or later (Released: July 10, 2026)
  2. MAGIC™ Engrave Laser 2 is v3.6.14 or later (Released: July 10, 2026)

Ring Scan Procedure

  1. Secure the ring.
  2. Select the ring template and enter the ring dimensions.

  1. In the Camera options, click "Refresh" button. The Rotary Image Scan window will open.

  1. Rotate the rotary to match the angle displayed in the software.
  2. Verify that the laser is properly focused on the ring surface.
  3. Click "Position Adjustment" button, then position the "H" marker at the area you want to scan.
  4. If the image is not detected correctly, adjust the Internal LED and Pointer Brightness.
  5. Select the scan quality. Scan time increases as the quality is set from Low to High.
  6. Click Start Scanning to start scanning.

  1. After the scan is complete, add text or other objects at the desired position, then proceed with laser marking.


Ring Scan Calibration

If the marking position is not accurate, you can correct it using the Fine Position Adjustment function.

  1. Click the Settings icon in the upper-right corner of the Rotary Image Scan window.

  1. Without moving the ring, perform the scan again.
    Compare the scanned position with the actual position of the ring, then enter the X and Y Offset values in the Detailed Settings window to correct the marking position.


Keypad Operation

Rotary Scan Preparation Mode

In Rotary Scan Preparation Mode, you can adjust the ring position and lighting before starting the scan.


Key Operation
FRONT / REAR Rotate the A-axis
LEFT / RIGHT Move the X-axis of the vise
UP/DOWN Move the Z-axis
F1 Adjust the Laser Pointer Brightness
F2 Turn the Head Pointer On/Off
F3 Adjust the Internal LED Brightness
F4 No function
START / ORG No function
END / STOP Cancel scan preparation

During Scanning

During scanning, most keypad functions are disabled to ensure safety and maintain scan stability.


Key Operration
END / STOP Stop scanning
All other keys No function

Precautions

Before scanning, make sure the laser is properly focused on the ring surface.
Incorrect focus may significantly reduce the accuracy of both the scan and the marking position.

For Inner Diameter scanning, adjust the rotary angle before setting the laser focus.

Enter the correct ring diameter and width.
These values directly affect the accuracy of the scan result and the marking position


Troubleshooting


If the system does not enter the Scan Ready Status
Check the device connection status, firmware version, and software version.

If the scanned image is unclear
Check the internal LED brightness and the reflective condition of the ring surface.

If the marking position is incorrect
First, check the laser focus. If the problem persists, perform the camera calibration again.