Keypad

s3keypad1.png


Direction
Key (X,Y)
Engraving area adjustment

(X) Moves X axis
(Y) Moves Y axis
Laser pointer Pointer On/Off Laser pointer On/Off
Pointer Calibration Set laser pointer calibration
Origin Origin change
(Short press button)
Current tool location
• Another location: Move to the origin
• Origin: Move to the another origin (Center ↔ Left-top origin)
Origin save
(Press and hold button for more than 5 seconds)
Save the current position as the origin.
Start Start marking button

• Start marking: Long-press (for 2 seconds) the [Start] button to start marking.

• Repeat marking: Press the [Start] button to finish marking, then double-press (tap twice) the [Start] button to repeat marking.

• Menu: Press OK when using the menu.
Auto focus Auto focus
(Short press button)
Activates camera auto focus position • Auto moves to view position after height measurement • Refreshes the camera display at MagicEngrave. ※Variety of features available for use once MagicEngrave software is enabled.
Touch sensor
-Tool Calibration-
(Press and hold button for more than 5 seconds)
Adjusts touch sensor settings
Stop Stops/cancels marking


Go to the S3 Descriptions➜