[MAGIC-E3] Calibration

Contents

※ The machine is initially set up at the factory. Please contact your reseller first before making any changes to the settings of the machine.
※ Only carbide and diamond tools can be calibrated. Do not calibrate tools such as endmill and cutter.
※ Be sure to unlock the pressure lock when calibrating the machine. Nose, tool and material can be damaged if the head is fixed or when the pressure lock is locked.


Tool change 1. Change the tool: Short-press to change tool.
2. Probe calibration: Long-press (for more than 5 seconds) to adjust probe settings.
Press the AF button while pressing/holding the corresponding button.
Pointer On/Off Laser pointer On/Off
Pointer calibration Set laser pointer calibration
/ Change Origin Current tool position • Another position: Move to the origin
• Origin: Move to a different origin (Center ↔ Left-top origin)

(more 3 seconds)
Save Origin Save the current position as the origin.

1. Touch Sensor (Tool Calibration)

  1. Place and secure the material on the clamp.

  1. Long-press and hold the e3main1.png button (for more than 5 seconds) to run probe calibration.

  1. Press e7main5.pnge7main6.png button to lower the tool. Lower down the tool until it comes into contact the material (placed at the center of the clamp).

  1. Lower the tool by using buttons or loosening the fixing bolt of the tool with a wrench, or lift the material with your hand to make the tool and material come in contact as shown in the picture below.

e7main8.png


  1. Long-press and hold e7main7.png button (for more than 3 seconds) until it beeps to confirm that the setting is saved then the tool will measure the material’s height.

Back to the contents➜

2 Laser Pointer Calibration

  1. Place and secure a flat material on the clamp.

  1. Press e7main2.png button while pressing/holding the e3main2.png button to run the laser pointer calibration.

  1. The tool draws a cross (+) line on the material and the laser pointer is turned on.

  1. Move the laser pointer to the center of the cross by using the e7main3.pnge7main4.pnge7main5.pnge7main6.png direction keys then press e7main7.png button.

e7main12.png

  1. The laser pointer moves closer to the material to calibrate the laser pointer’s origin. Move the laser pointer to the center of the cross by using the e7main3.pnge7main4.pnge7main5.pnge7main6.png direction keys on the engraving machine then long-press and hold the e7main7.png button (for more than 3 seconds) until it beeps to confirm that the setting is saved.

Back to the contents➜

3 Saving Multi-performance Clamp Origin Position

  1. Press e7main6.png button while pressing/holding the e3main2.png button to turn on the laser pointer.

  1. Once the laser pointer is on, use e7main3.pnge7main4.pnge7main5.pnge7main6.png direction keys to move the pointer to the desired position on the clamp then designate the position as origin.

Origin1- Center

e7main19.png

Origin2- Additional

-Use the e7main3.pnge7main4.pnge7main5.pnge7main6.png direction keys to move to the position to save as the origin.


  1. Press e7main7.png button while pressing/holding the e3main2.png button (for more than 3 seconds) to save the current position as origin.

Back to the contents➜

4 Camera calibration

Bakelite plate
(120x100x2t)
  1. Camera can be calibrated in the MagicEngrave program.

e7main39.png

  1. Use the e7main5.pnge7main6.png button to adjust the red line (that appears on the screen) to center of the clamp. Once the red line is adjusted to the center, click Next.

e7main40.png

  1. Place and secure the bakelite to the clamp. Set the calibration area to 90 x 70mm then click Create Line. Check the calibration results then click OK.

e7main41.png

  1. Press and hold the e7main4.png button (for more than 3 seconds) until it beeps to start engraving. A rectangle will be engraved for calibration.

  1. Align the red corner marks to the calibration line corners with the mouse or keyboard.

e7main42.png

  1. Check the calibration results on the program. Be sure that the red lines are marked over the calibration lines. Click OK to complete the calibration.

e7main43.png

Back to the contents➜